How to Judge Quickly DC Motor Stator Testing Machine With Pneumatic Fixture

SHANGHAI WIND AUTOMATION
How to Judge Quickly DC Motor Stator Testing Machine With Pneumatic Fixture
Contact our team for pricing, availability and machine configuration.
Request A Quote| Condition: | New | Test Product: | Generator Alternator Stator |
|---|---|---|---|
| Working Station: | Double Station | Testing Item Content Display: | Dispositivos Testador |
| HS Code:: | 9030390000 | After Sales Service: | Engineer Available For Oversea Service |
| Highlight: |
DC motor stator tester with pneumatic fixture, armature testing machine with pneumatic clamp, stator testing equipment for DC motors |
||
DC motor Stator Testing Machine Quality Analysis WIND-DTS

1. Advantage
1) Fast clamping fixture can be fitted for 3 terminal wires
2) Pneumatic fixutre is widely used to test 3 terminal wires or 6 end wires
2.Testing item: all the testing items can be conducted alone or together.
1)DC resistance test
Testing range:0.01W – 1000W
Testing loop:6 loop(scalable)
Tolerance:±0.5 %
Testing method:Four points, with auto ambient temperature correction function
2)Inductance test(including 3 phase balance test)
Testing range:10mH – 500mH
Testing loop:6 loop(scalable)
Tolerance: ±2.5%
Testing method:Four points
3)Turn to turn insulation
Pulse high voltage: 100V-3000V (100V / step)
Pulse peak: 0.5msec
Sampling frequency: 1-40 MHZ
Testing loop:6 loop(scalable)
Tolerance: ±2.5%
Judging method: area difference judgment (sensitive to inductance and energy loss)
Standard waveform is White,OK waveform is Green, NG waveform is Red
4)Insulation resistance
Voltage:DC500V /1000V
Testing time:1-10s(adjustable)
Judging range:1-1000 MW
Tolerance: ±2.5%
5)Interphase insulation
Voltage:DC500V /1000V
Testing time:1-10s(adjustable)
Judging range:1-1000 MW
Tolerance: ±2.5%
6)Interphase hipot
Voltage:AC100-3000V (100V/step)
Testing time:1-10s(adjustable)
Judging range:0.1 mA — 20 mA
Tolerance: ±2.5%
7)Hipot(with arc detection)
Voltage:AC100-3000V (100V/step)
Testing time:1-10s(adjustable)
Judging range:0.1 mA — 20 mA
Tolerance: ±2.5%
8)Balance of resistance
Test method: DC resistance sampling
Testing time:0.1s
Judging method:percentage method adopted to judge the difference of DC resistance between windings.
3.Testing time
| Item | DC resistance | Balance of resistance | Turn to turn short circuit | Insulation resistance | Hipot | Interphase insulation | Interphase hipot |
| Parameter | 0.05s/loop | 0.1s/time | 1 impulse/ time | 1s/time | 1s/time | 1s/time | 1s/time |
| Time | 1.5s/6 loop | 0.1s | 1s | 1s | 1s | 1s | 1s |