Shanghai Wind Automation Equipment Co.,LtdSales & Support: Request A Quote  |  English
Wind AutomationSTATOR WINDERShanghai Wind Automation Equipment Co.,Ltd
emily@motor-machinery.com+86 21 5899 2293

DC Voltage Armature Testing Equipment Winding Machine Fully Automatic

SHANGHAI WIND AUTOMATION

DC Voltage Armature Testing Equipment Winding Machine Fully Automatic

Contact our team for pricing, availability and machine configuration.

Request A Quote
Detailed Product Description
Condition: New Test Item: DC Resistance, Surge, Hi-pot
Working Station: Double Station Automation Type: Fully Automatic
Testing Item Content Display: Test Result Intuitive Display On Screen One By One Armature Slots: 13, 17, 19 (few), 21,23,25,27, 28,29,33slots (common)
Highlight:

high voltage test equipment

,

armature testing machine

Starter Armature Testing Machine Belt Spins The Rotor During The Test WIND-ATS-02

 

 

 

(1) Application

 

Starter armature upto 36 slots

 

covering 13, 17, 19 (few), 21,23,25,27, 28,29,33 slots (common)

 

 

 

(2) Competitive Advantages

 

1. Moden concept initial positioning, comparing to tranditional starter armature tester,

 

    the operator no need to check initial positioning manually, 

 

    Make the testing convenient and easier.

 

2. 100% Satisfied feedback from starter armature manufacturers. 

 

 

 

(3) Technical Data

 

1. Bar to Bar resistance,0.01mΩ~10mΩ (Out of range display OVER)

 

    Four-terminal measurement to ensure accuracy

 

2. Welding resistance,0.001mΩ-10mΩ (Out of range display OVER)

 

   Six-terminal measurement to ensure accuracy

 

3. Cross resistance 0.01mΩ-10mΩ

 

    Four-terminal measurement to ensure accuracy

 

4. Surge 100-1000V (100V/time)

 

    Pulse crest:0.5u sec, Frequency 1~40MHz

 

    Standard waveform is Write, OK waveform is Green, NG waveform is Red

 

5. Isolation resistance DC 500V

 

   Testing time:1~10s (0.1s/time)

 

   Range:1~500MΩ

 

   Accuracy: ≤±5%

 

   DC Voltage insulation has the advantages such as it has little insulation damage to the tested product,

 

   The leakage current can be measured simultaneously in the measurement of insulation and it is easy to 

 

   find the end of the motor insulation leakage.

 

6. Hipot AC 100-1000V

 

   Testing time:1~10s (0.1s/time)

 

    Armature commutator bars ≤ 36 bars

 

   Testing panel cycle time: 8~9s (according to 33 bars)

 

   13, 17, 19 (few), 21,23,25,27, 28,29,33 slots (common)

 

Test Items Test Description Test result
Bar to Bar resistance 0.01mΩ~10mΩ ≤±0.5% Full scale
Welding resistance 0.01mΩ-10mΩ ±10μΩ
180℃ cross resistance 0.01mΩ-10mΩ ≤±1.5% Full scale
Surge 100-1000Vpp (Max 36sets waveform) ±5%
Isolation resistance DC 500V

0.1-500MΩ

≤±5% Full scale

Hipot AC 100-1000V

0-20mA

≤±.5% Full scale

 

 

 

(4) Main Configuration

 

15’’ Touch screen Sampling Chip: BB Relay:NAIS High voltage relay:Meder

 

Pneumatic parts:Airtec

 

Power: AC 220V,50Hz

 

Air pressure:0.4~0.6MPa

 

Temperature:0~45℃

 

Dimension: 950mm*1250mm*580mm

 

HS Code:9030390000

 

 

 

(5) Inspection report before delivery

DC Voltage Armature Testing Equipment Winding Machine Fully Automatic 0

DC Voltage Armature Testing Equipment Winding Machine Fully Automatic 1

 

 

 

Please click below link to view video

https://youtu.be/wspDmeOKfoo

 

 

 

Tag:

electronic test equipment,

compression testing machine,